Temperature profiles inside vessels and reactors
Measure temperature at several positions within a reactor, vessel or process column. TE Instrumentation designs and manufactures Thermo Electric multipoint, or multilevel, temperature sensors around the required measuring-point locations, process connection and maintenance access. Thermocouple and Pt100 constructions are selected to suit the measurement task.
Multipoint Sensors for your application
Measuring temperature across the process
Locate measuring points where they provide useful information about the reactor or vessel temperature profile. Share the vessel drawing, internal obstructions, process conditions and required positions so that the sensor layout can be reviewed.
Multiple measurements through a defined installation
Multipoint assemblies are used in chemical, petrochemical and refining processes, including fractionation towers and pilot plants. Specify the installation opening, point count, insertion length and access available for fitting or replacing the assembly.
Pilot plant assemblies
Compact protection-tube constructions for pilot plants. Specify the number of thermocouples, insertion length and point spacing to match the test equipment.
Spring-loaded strips
Thermocouple or Pt100 elements are held against the protection-tube wall. Review the contact arrangement and response requirements for each measurement point.
Replaceable inserts
Guide and support tubes can allow individual inserts to be removed. The maintenance arrangement and process isolation must be confirmed for the complete assembly.
Radial multipoint assemblies
Radial thermocouple placement provides measuring locations across a vessel. Agree the layout, materials and installation requirements for the process profile you need.
Engineering, testing and service support
Measurement-point layout
Supply a vessel or reactor drawing with each required measuring position. We review the sensor arrangement, installation route and connection details around the available space.
Inspection and documentation
Agree the mechanical and electrical checks, calibration requirements and documentation before manufacture. Hazardous-area certification must be matched to the specific configuration and installation.
Maintenance planning
Consider insert replacement, handling length and process isolation during specification. Removal without interrupting operation applies only where the selected construction and installation permit it.
Specifying multipoint sensors
Points & layout
Elements & protection
Connection & service
Tests & certificates
Specify the number of measuring points and their positions along or across the vessel. Include insertion length, internal supports, access openings and any equipment that the assembly must pass during installation.
The aim is a useful process profile. More points alone do not establish that the selected locations represent the temperatures relevant to your process.
The brochure includes thermocouple and Pt100 constructions. Choose the element type around the temperature range, measurement system and response requirements. Specify the protection-tube material and dimensions for the process atmosphere and mechanical duty.
The temperature handbook explains that protection, installation and the measuring system all affect the result. Review the complete measurement chain rather than treating the sensing element as the only selection variable.
Supply the process connection, sealing arrangement, junction-box location and electrical termination details. For replaceable inserts, agree guide-tube construction and the space needed to withdraw the insert.
Do not assume that every multipoint design allows online replacement. The pressure boundary, maintenance procedure and selected construction must be reviewed together.
Agree the required mechanical and electrical tests, calibration points and certificate package with your enquiry. Include any inspection plan, material traceability or hazardous-area requirements.
Confirm the approvals applicable to the actual assembly. Generic company certificates or approval tables do not establish suitability for every configuration.
Are multipoint and multilevel sensors the same?
Both terms describe assemblies that measure temperature at several locations. The number, position and arrangement of the points depend on the vessel and the process profile required.
Can the measuring points be customised?
Point count, spacing, insertion length and construction can be reviewed against your drawing. Include the measurement locations and installation constraints rather than only an overall sensor length.
Can thermocouples and Pt100 elements be used?
The brochure describes thermocouple and Pt100 constructions. Selection depends on temperature, response requirements, installation and the connected measurement system.
Can inserts be replaced while the process runs?
Some thermowell and guide-tube designs allow insert removal without interrupting the process. This must be confirmed for the selected assembly, isolation arrangement and maintenance procedure.
What is a radial multipoint assembly?
A radial arrangement places thermocouple measuring points across the vessel. The radial assembly described in the brochure is reviewed around the required point layout, materials and installation.
What information is needed for an enquiry?
Send the vessel drawing, process temperature and pressure, medium, required measurement points, connection details, access constraints and the calibration or documentation requirements.
Brochures and technical resources
Multipoint Sensors brochure (PDF)
Related sensor routes: Tube Skin Thermocouples | Thermowells & Pockets | High-Pressure Sensors | All Industrial Sensors | Calibration