Specification Summary
- Series: OTP-60.000.
- Probe type: mineral insulated single or duplex thermocouple, welded on mounting bush.
- Thermocouple types: iron-constantan type J, chromel-alumel type K, and copper-constantan type T.
- Accuracy: ASTM E230/ANSI MC96.1 standard limits of error; IEC 60584 Class 2.
- Insulation material: densely packed MgO, 99.6% purity.
- Sheath material: SS 316 for type J and T (Wstnr.1.4301), and Inconel 600 for type K (Wstnr.2.4816); other materials available.
- Hot junction: insulated, common insulated for duplex.
- Minimum insulation resistance: 10 Mohm at ambient temperature with 200 V DC.
- Connection head: Thermo Electric weatherproof cast aluminium head.
- Cable entry: 3/4 inch NPT female thread.
- Process connection: 1/2 inch NPT.
- Probe length 'A': to be specified; replace box in ordering code with your required length.